Benutzer-Werkzeuge

Webseiten-Werkzeuge


doku:wechselrichter:wr7ktl11

? (WR7kTL11)

Spot Channels

Device 'WR7KTL11 SN:2000576180' has 18 Spot channels:
Reading channel values, please wait...
------------------------------------------------------------
Channel handle |    Channel name    | Channel value (Unit) |
------------------------------------------------------------
      57       | '         Upv-Ist' | '491.000000' (V) 
      58       | '        Upv-Soll' | '474.000000' (V) 
      59       | '         Iac-Ist' | '2.228000' (A) 
      61       | '             Uac' | '2255.000000' (V) 
      62       | '             Fac' | '50.009999' (Hz) 
      63       | '             Pac' | '502.000000' (W) 
      64       | '             Zac' | '0.304000' (Ohm) 
      66       | '            Riso' | '10000.000000' (kOhm) 
      71       | '             Ipv' | '1.120000' (A) 
      82       | '         E-Total' | '488.592023' (kWh) 
      83       | '         h-Total' | '816.107883' (h) 
      84       | '            h-On' | '934.129565' (h) 
      85       | '        Netz-Ein' | '283.000000'    
      87       | '    Seriennummer' | '2000576180.000000'    
      88       | '          Status' | 'Mpp'    
      89       | '           Phase' | '-------'    
      90       | '        Balancer' | 'Off'    
      91       | '          Fehler' | '-------'

Parameter Channel

Device handle: Device 'WR7KTL11 SN:2000576180' has 19 Parameter channels:
Reading channel values, please wait...
------------------------------------------------------------
Channel handle |    Channel name    | Channel value (Unit) |
------------------------------------------------------------
       3       | '          SMA-SN' | '2000576180.000000'    
       4       | '       Upv-Start' | '400.000000' (V) 
       5       | '         T-Start' | '10.000000' (s) 
       6       | '          T-Stop' | '2.000000' (s) 
       7       | '     Usoll-Konst' | '500.000000' (V) 
      10       | '          Plimit' | '7000.000000' (W) 
      23       | '    Software-BFR' | '3.120000' (Version) 
      24       | '    Software-SRR' | '3.120000' (Version) 
      25       | '  SMA-Grid-Guard' | '2.061000' (Version) 
      37       | '      T-Stop-Fan' | '50.000000' (grdC) 
      38       | '     T-Start-Fan' | '70.000000' (grdC) 
      39       | '       T-Max-Fan' | '90.000000' (grdC) 
      42       | '  Ripple-Ctl-Lev' | '8.000000' (%) 
      43       | '  Ripple-Ctl-Frq' | '1605.000000' (Hz) 
      50       | '     Betriebsart' | 'Mpp-Betrieb'    
      53       | '         Default' | 'GER/VDE0126-1-1'    
      54       | '   Netzanschluss' | '-----'    
      55       | ' Ripple-Ctl-Rcvr' | 'auto'    
      56       | '   PowerBalancer' | 'Off'
doku/wechselrichter/wr7ktl11.txt · Zuletzt geändert: 2014/06/19 22:47 (Externe Bearbeitung)